Ultra3000 system component overview, Low voltage directive – Rockwell Automation 2090 Ultra3000 Installation Manual User Manual

Page 27

Advertising
background image

Publication 2098-IN003E-EN-P — April 2004

Installing Your Ultra3000

1-3

Low Voltage Directive

These units are tested to meet Council Directive 73/23/EEC Low
Voltage Directive. The EN 60204-1 Safety of Machinery-Electrical
Equipment of Machines, Part 1-Specification for General Requirements
standard applies in whole or in part. Additionally, the standard
EN 50178 Electronic Equipment for use in Power Installations applies
in whole or in part.

Refer to Appendix B for interconnect information.

Ultra3000 System
Component Overview

This section provides an overview of the Ultra3000 system
components and a typical installation.

Note: Refer to Appendix C for a complete list of catalog numbers for

the Ultra3000 system components listed above.

Ultra3000 System
Component

Catalog Numbers

Description

Ultra3000

Drives

2098-DSD-xxx and -xxxX

Ultra3000 and Ultra3000 with indexing available with 500W, 1, 2, 3, 7.5 and 15 kW continuous output
and 230V input power.

2098-DSD-HVxxx, and
-HVxxxX

Ultra3000 and Ultra3000 with indexing available with 3, 5, 10, 15, and 22 kW continuous output and
460V input power.

Ultra3000-SE
SERCOS interface
Drives

2098-DSD-xxx-SE

Ultra3000 with SERCOS interface available with 500W, 1, 2, 3, 7.5 and 15 kW continuous output and
230V input power.

2098-DSD-HVxxx-SE

Ultra3000 with SERCOS interface available with 3, 5, 10, 15, and 22 kW continuous output and 460V
input power.

Ultra3000-DN
DeviceNet Drives

2098-DSD-xxx-DN and
-xxxX-DN

Ultra3000 with DeviceNet and Ultra3000 with indexing DeviceNet available with 500W, 1, 2, 3, 7.5
and 15 kW continuous output with 230V input power.

2098-DSD-HVxxx-DN and
-HVxxxX-DN

Ultra3000 with DeviceNet and Ultra3000 with indexing DeviceNet available with 3, 5, 10, 15, and 22
kW continuous output with 460V input power.

ControlLogix/
SoftLogix Platforms

1756-MxxSE module

1784-PM16SE PCI card

The SERCOS interface module/PCI card serves as a link between the ControlLogix/SoftLogix platform
and Ultra3000 system. The communication link uses the IEC 61491 SErial Real-time COmmunication
System (SERCOS) protocol over a fiber-optic cable.

RSLogix™ 5000
software

9324-RLD300ENE

RSLogix 5000 provides support for programming, commissioning, and maintaining the Logix family of
controllers.

Ultraware Software

2098-UWCPRG

The Ultra3000 Analog and DeviceNet drives are configured using Ultraware software.

Servo Motors

MP-Series, 1326AB,

F-, H-, N-, and Y-Series

The MP-Series (Low Inertia, Integrated Gear, and Food Grade) 230 and 460V, 1326AB (M2L/S2L) 460V,
and F-, H-, N-, and Y-Series 230V motors are available for use with the Ultra3000 drives.

Cables

Motor Power, Feedback,
and Brake cables

Motor power, feedback, and brake cables include integral molded, bayonet style, quick connect/
quick-release connectors at the motor. Power and brake cables have flying leads on the drive end and
straight connectors that connect to servo motors. Standard feedback cables have angled connectors
(45º) on the drive end and straight connectors that connect to servo motors.

Fiber-Optic cables

SERCOS fiber-optic cables are available in enclosure only, PVC, nylon, and glass with connectors at
both ends.

AC Line Filters

2090-UXLF-xxx

AC line filters with 6, 10, 23, 32, 36, and 50A are available for Ultra3000 (230V) drive systems.

2090-UXLF-HVxxx

AC line filters with 23, 30, and 50A are available for Ultra3000 (460V) drive systems.

External Shunt
Modules

2090-UCSR-xxxx,
9101-1183, and

2090-SRxxx-xx

External shunt modules are available when the Ultra3000 internal shunt capability is exceeded.

Advertising
This manual is related to the following products: