Publication 2098-IN003E-EN-P — April 2004

Connecting Your Ultra3000

3-19

Wiring Motor Power

When using MP-Series (low inertia and integrated gear), 1326AB, and
F-, H-, or N-Series motors refer to Figure 3.16 for your motor power
cable configuration. Refer to Appendix B for the motor/drive
interconnect diagrams.

Figure 3.16
Motor Power Cable (MPL-A/B,
MPG-A/B, 1326AB, and F-, H-, or N-Series Motors)

1

Motor cable leads (shortest to longest) are labeled differently, depending on the drive input voltage (230V/460V).

When using MP-Series (food grade) motors, the brake wires are
included in the motor power cable (2090-XXNPMF-xxSxx), as shown
in Figure 3.17. Refer to Appendix B for the motor/drive interconnect
diagram.

Figure 3.17
Motor Power Cable (MPF-A/B Food Grade Motors)

When using Y-Series motors, the brake wires are included in the
motor power cable (2090-XXNPY-16Sxx), as shown in Figure 3.18.
Refer to Appendix B for the motor/drive interconnect diagram.

Figure 3.18
Motor Power Cable (Y-Series Motors)

2090-XXNP

xx-xxSxx

2090-UXNPA/PB

xx-xxSxx

V

Exposed Braid

4 mm

2

(12 AWG) conductors or larger

1.5 or 2.5 mm

2

(16 or 14 AWG) conductors only

Black

Black

Green/Yellow

Green/Yellow

Brown

Blue

U or W

1

Brown or Blue

W or U

1

Blue or Brown

Exposed Braid

BR+
BR-

2090-XXNPMF

xxSxx

Cable Shield

(overall)

Brown

Black

Blue

Green/Yellow

Cable Shield

(for brake wires)

2090-XXNPY-16S

xx

Exposed Braid

Brake Wires

Green/Yellow

Black 1

Black 2

Black 3

Black 9

Black 7