Working with the PanelView e Transfer Utility 32

Publication 2711E-UM003B–EN–P

Remote I/O Pass-Through Transfers

The Remote I/O Pass-Through feature enables you to download a
PanelBuilder Remote I/O application file from your computer over
the Data Highway Plus (DH+), ControlNet, or Ethernet networks and
then over the Remote I/O network, to a PanelView terminal. You can
do this without connecting the serial cable to the terminal and
without going from terminal to terminal with a PC.

You need the same equipment for Remote I/O Pass-Through
transfers over either DH+, ControlNet, or Ethernet as listed
previously for the DH+ and ControlNet networks. In addition, you
need one of the following:

for a DH+ transfer, a PLC-5 or SLC-5/04 processor is required
(for PLC/SLC series/revision requirements, refer to Chapter 5 of
the PanelView 1000e, 1200e, and 1400e Operator Terminals User
Manual
)

for a ControlNet transfer, a PLC-5C or PLC5C15 processor is
required (for PLC series/revision requirements, refer to Chapter 5
of the PanelView 1000e, 1200e, and 1400e Operator Terminals
User Manual
)

for an Ethernet transfer, a PLC-5E processor or a 1785-ENET
sidecar module is required (for PLC series/revision requirements,
refer to Chapter 5 of the PanelView 1000e, 1200e, and 1400e
Operator Terminals User Manual
)

You also need RSLinx Lite software, Version 2.0 or later. RSLinx
Lite is included with your PanelBuilder 1400e software package
(A-B Catalog Number 2711E-ND1) or Transfer Utility software
package (A-B Catalog Number 2711E-ND7).

Figures 2.8 and 2.9 show how the application file is transferred from
the development computer to the PLC and then to the PanelView
terminal.

Figure 2.10 shows how the application file is transferred through an
Ethernet link, over the Remote I/O network, and then to the
PanelView terminal.