Chapter

3

Uploading 1000e/1200e/1400e
Application Files and Alarm
History Files

This chapter describes how to upload PanelView application files
and alarm history files from the PanelView terminal to your
computer, using the various transfer methods.

You can upload application files using either a serial connection, a
network connection, or a Remote I/O connection. For serial transfers,
you must connect the PanelView terminal to a computer with the
Upload/Download cable (Allen-Bradley Catalog Numbers
2706-NC13, 2711-NC13, 2711-NC14 for PanelView 1000e
terminals; 2711-NC1 for PanelView 1200e/1400e terminals). For
network transfers, you must connect the PanelView terminal to the
computer over a DH+ or ControlNet network. For Remote I/O
transfers, you must connect the PanelView terminal to the PLC over
a Remote I/O network, and connect the PLC to the computer over a
DH+, ControlNet, or Ethernet network.

To upload application files, you must complete these steps in order:

prepare the PanelView terminal for a serial, network, or RIO
Pass-Through upload

Important:

For network uploads, you do not need to
configure the parameters on the PanelView
terminal. PanelView uses the parameter settings
for the currently-selected file.

configure the PanelView e Transfer Utility 32 for the upload

initiate the application file upload

Uploading PanelView
1000e/1200e/1400e
Application Files