5–15

Configuring Communications Settings for 1000e/1200e/1400e Application Transfers

Port
Specify COM1, COM2, COM3, or COM4 as the serial port used
to connect the serial cable to the 1770-KF2/KE or 1770-KFC.
The default setting is COM1.

Parity
Specify None or Even for the type of error-checking to be used.
This must match the parity configured for the 1770-KF2/KE or
1770-KFC. The default setting is None.

Error
Specify the error-detection protocol used by the device. BCC is
Block Check Character and CRC is Cyclic Redundancy Check.
This must match the error-checking protocol configured for the
1770-KF2/KE or 1770-KFC. The default setting is BCC.

To set the device type:

"

Select a device type from the list.

The device type is the PLC to which the PanelView terminal is
connected over Remote I/O. For DH+ Remote I/O Pass-Through,
the default device is PLC-5/11 Integral. For ControlNet Remote
Pass-Through, the default device is PLC-5/20. For Ethernet
Remote Pass-Through, the default device is PLC-5/20.

To set the transfer path:

Set the transfer path using one of the following methods:

enter the transfer path manually

use Station Browse to start RSWho

use the transfer path value from a runtime PV file

To set the transfer path manually:

"

If you know the transfer path, enter it in the Transfer Path box.
See Appendix A for transfer path formats.

You cannot enter a transfer path manually for file transfers over
ControlLogix Gateway bridging.

To set the transfer path using Station Browse:

1. Click Station Browse to start RSWho.

2. Highlight the device name.

3. Click OK. The transfer path you selected in RSWho is displayed

in the Transfer Path box in the Configure Transfer Method dialog
box.