Rockwell Automation 2711E-ND7 PanelView File Transfer Utility User Manual User Manual

Page 64

Advertising
background image

4–2

Downloading 1000e/1200e/1400e Application Files

To prepare the PanelView terminal for a serial download:

1. Using the hardware keyswitch or the Goto Configure Mode

button, switch the PanelView terminal to the Configure mode.

2. In the Terminal Configuration screen, choose the Transfer Setup

button to display the Transfer Setup screen.

3. To change the settings, choose the Baud Rate, Parity, or Error

buttons to move the check mark to the setting you want.

Baud Rate

ĊThe speed at which data is transmitted over the

serial cable. The default setting for a serial transfer is
9600 baud.

Parity

ĊUsed to check for accurate transmission of the data

between the development computer and terminal. The default
setting is None.

Error

ĊUsed to check for errors in the data transmission.

Error checking is either

CRC

Ċcyclical (or cyclic) redundancy check.

BCC

Ċblock check character. BCC is the default setting.

The settings that are defined in the Transfer Setup screen must
match the Transfer Utility’s settings.

4. When you have selected the required settings, choose OK to exit

this screen.

5. To download an application serially, in the Terminal

Configuration screen, choose the Transfer Application button to
display the Transfer Application screen.