Rockwell Automation 2711E-ND7 PanelView File Transfer Utility User Manual User Manual

Page 84

Advertising
background image

5–12

Configuring Communications Settings for 1000e/1200e/1400e Application Transfers

Parity
Specify None or Even for the type of error-checking to be used.
This must match the parity configured for the 1770-KF2/KE or
1770-KFC. The default setting is None.

Error
Specify the error-detection protocol used by the device. BCC is
Block Check Character and CRC is Cyclic Redundancy Check.
This must match the error-checking protocol configured for the
1770-KF2/KE or 1770-KFC. The default setting is BCC.

To set the transfer path:

Set the transfer path using one of the following methods:

enter the transfer path manually

use Station Browse to start RSWho

use the transfer path value from a runtime PV file

To set the transfer path manually:

"

If you know the transfer path, enter it in the Transfer Path box.
See Appendix A for transfer path formats.

You cannot enter a transfer path manually for file transfers over
ControlLogix Gateway bridging.

To set the transfer path using Station Browse:

1. Click Station Browse to start RSWho.

2. Highlight the device name.

3. Click OK. The transfer path you selected in RSWho is displayed

in the Transfer Path box in the Configure Transfer Method dialog
box.

To set the transfer path using Runtime PV File:

"

See “Obtain Transfer Parameters from an Application File” in
this chapter for details.

Advertising