Downloading 1000e/1200e/1400e Application Files

To configure the PanelView e Transfer Utility 32 for the download:

1. In the PanelView e Transfer Utility 32, choose the Download tab

from the main dialog box.

2. In the Source File box, type the full path and file name of the

download file, or choose Browse to locate a file on the disk. The
file must be a .pvd file created by PanelBuilder 1400e.

A .pvd file may already be displayed in the Source File box. If
you started the Transfer Utility from PanelBuilder 1400e, the
source file defaults to the current application in PanelBuilder. If
you started the Transfer Utility separately, the source file defaults
to the last source file you had saved using Auto-Save All
Settings.

3. In the Terminal Storage box, choose the memory area where the

downloaded application will be stored. The default is Memory
Partition 2.

Memory Partition 1 is the terminal’s first memory partition. It is
typically used for firmware storage and is not available for
application file storage, unless the firmware is located on a
PCMCIA card.

Memory Partition 2 is the terminal’s second memory partition.
It can only be used for application file storage.

Card Partition 1 is the first partition on a card with two
application partitions or the partition on the card with a single
partition. If the firmware is located on a PCMCIA card, then this
storage area is not available for applications.

Card Partition 2 is the second partition on a card with two
application partitions.