Install 3s-3000/f/sgs drill cables, Route cables, Dress and secure cables – Great Plains Electric Clutch Package User Manual

Page 64: Rl s c n/c t j h

Advertising
background image

60

Electric Clutch Package

Great Plains Manufacturing, Inc.

195-073M

03/24/2009

Install 3S-3000/F/SGS Drill Cables

Refer to Figure 94 (dimensions are inches)
8.

From the bundle:

833-294C 40P PNT RW CLTCH CNTRL & HRNSS

select the drill harness

. which is a long cable

assembly with 7 connectors.

9.

Select all of:

800-082C CABLE TIE .31X21.5 6DIA 120LB

10. Fish your cable snake through the tongue tube.

Wrap hitch connectors

of the harness so that

they cannot snag, and secure that end of the har-
ness to the rear end of the snake.

Route Cables
11. Pull the cable forward until it appears at the hitch end

of the tongue tube. Continue pulling until:
there is ample slack for making tractor connections
at the hitch, but not so much that the cable can touch
the ground in operations, and do not pull the first
cable junction

into the tube.

12. Route the rear end of the cable, following hydraulic

hoses, to the right clutch.

13. Mate harness connector “Right”

to the jumper

cable on the right clutch.

14. Route the “Center” cable leg

to the center section

clutch. Mate the connectors.

15. Route harness cable leg “Height Switch”

down to

the switch mounted under the center section, and
mate the connectors.

16. Route harness cable leg “Left”

back to drill cen-

ter, and out to the left clutch. Route across the rear
of the tongue, and not across the gap between the
wing tool bars. Mate connector

to the left clutch

jumper cable.

Dress and Secure Cables
17. Dress cables to prevent entanglement with or chaf-

ing by drill moving parts. Leave ample slack at drill
center for folding (ideally, route the wing cables
directly above wing pivot center lines). Coil any
excess cable at drill center.

18. At the hitch end of the harness, use one cable tie

to secure the harness to clamped hydraulic hoses.

19. Use 1 tie to secure the switch lead and harness

switch leg.

20. Use 4 ties on each wing to secure the wing runs.

21. Near the right wing pivot, coil the unused “PUMP” (or

unlabeled) cable leg

and any excess cable. Use

one tie to secure them.

Figure 94

3S-3000/F/SGS Drill Cabling

28096

R

L

S

C

n/c

T

J

H

56

H

28

H

J

R

C

S

L

L

28

n/c

Advertising