Install 3s drill cables, Route cables, Dress and secure cables – Great Plains Electric Clutch Package User Manual
Page 93: Rl s c n/c t j h
Great Plains Manufacturing, Inc.
3S-4000 Electrical Installation
89
03/24/2009
195-073M
Install 3S Drill Cables
Refer to Figure 144 (dimensions are inches)
8.
From the bundle:
833-294C 40P PNT RW CLTCH CNTRL & HRNSS
select the drill harness
. which is a long cable
assembly with 7 connectors.
9.
Select all of:
800-082C CABLE TIE .31X21.5 6DIA 120LB
10. Fish your cable snake through the tongue tube.
Wrap hitch connectors
of the harness so that
they cannot snag, and secure that end of the har-
ness to the rear end of the snake.
Route Cables
11. Pull the cable forward until it appears at the hitch end
of the tongue tube. Continue pulling until:
there is ample slack for making tractor connections
at the hitch, but not so much that the cable can touch
the ground in operations, and do not pull the first
cable junction
into the tube.
12. Route the rear end of the cable, following hydraulic
hoses, to the right clutch.
13. Mate harness connector “Right”
to the jumper
cable on the right clutch.
14. Route the “Center” cable leg
to the center section
clutch. Mate the connectors.
15. Route harness cable leg “Height Switch”
down to
the switch mounted under the center section, and
mate the connectors.
16. Route harness cable leg “Left”
back to drill cen-
ter, and out to the left clutch. Route across the rear
of the tongue, and not across the gap between the
wing tool bars. Mate connector
to the left clutch
jumper cable.
Dress and Secure Cables
17. Dress cables to prevent entanglement with or chaf-
ing by drill moving parts. Leave ample slack at drill
center for folding (ideally, route the wing cables
directly above wing pivot center lines). Coil any
excess cable at drill center.
18. At the hitch end of the harness, use one cable tie
to secure the harness to clamped hydraulic hoses.
19. Use 1 tie to secure the switch lead and harness
switch leg.
20. Use 4 ties on each wing to secure the wing runs.
21. Near the right wing pivot, coil the unused “PUMP” (or
unlabeled) cable leg
and any excess cable. Use
one tie to secure them.
Figure 144
3-Section Drill Cabling
28096
R
L
S
C
n/c
T
J
H
H
H
J
R
C
S
L
L
n/c