General Information

These packages replace the standard lift-actuated
mechanical clutches on each section with electric
clutches control both by a single drill lift switch and by
cab module section switches. This is an alternative way
to provide point row capability, where point row opera-
tions do not require raising the non-planting sections

These instructions explain how to install an Electric
Clutch Package, provided as one of four kits:

Note: These instructions do not cover the case of adding

electric clutches to a drill which has previously had
the Point Row option installed. In such an unlikely
case, please have the Great Plains dealer contact
the factory for further instructions.

Each kit updates one drill. Kits are specific to the number
of drill sections, and on 2S-2600, whether or not the
Small Seeds and/or Fertilizer Options are also present:

Notations and Conventions

“Left” and “Right” are facing in the direc-
tion of machine travel. An orientation rose
in many figures shows the directions of
Left, Right, Front, Back, Up, Down.

Note: Many figures show fully exploded views. Remove

only specified parts.

A crucial point of information related to the preceding
topic. Read and follow the directions provided before
continuing, to ensure safety, avoidance of machine
damage, and to achieve desired field results.

Note: Useful information related to the preceding topic.

A glossary of abbreviations used in part descriptions is
available on page 98.

Call-Outs

Kit

Kit Description

195-075A

3S-40 ELEC CL PKG SML SDS-FERT

195-076A

2S-2600 ELEC CLUTCH PKG

195-077A

2S-26 ELEC CL PKG SML SDS-FERT

195-078A

3S-3000 ELECTRIC CLUTCH PKG

Drill Model

Drill

Vintage

Small

Seeds

Uses

Kit

2S-2600

s/n DD1152+

No

195-076A

2S-2600HD

any

2S-2600

s/n DD1152+

Yes

195-077A

2S-2600HD

any

2S-2600F

s/n DD1152+

n/a

2S-2600HDF

any

3S-3000
3S-3000F

1996+, s/n S1563+

any

195-078A

3S-3000HD
3S-3000HDF

any

4S-4000
4S-4000F

s/n YY1152+

any

195-075A

4S-4000HD
4S-4000HDF

any

U

D

L

R

B

F

-

,

-

Single-digit/letter callouts identify compo-
nents in the currently referenced Figure or
Figures. These references are reused for dif-
ferent items from section to section.

to

Two-digit callouts in the range 11 to 61 refer-
ence new parts from the new parts lists
beginning on page 94. The descriptions
match those on the parts, bags or cartons,
and in your updated Parts Manual.

to

Three-digit callouts in the range 101 to 138
reference affected existing parts from the
table on page 97. The descriptions match
those in your Parts Manual. The narrative
and table indicate any re-use of the parts.

1

9

a

z

11

61

101

138