Dell POWEREDGE M1000E User Manual

Page 432

Advertising
background image

432

Monitoring Switch Traffic

rmon alarm

number

variable interval

{absolute |delta} rising-

threshold

value [event-

number] rising-

threshold

value [event-

number] [startup

direction] [owner string]

Add an alarm entry

number — The alarm index. (Range: 1–65535)

variable — A fully qualified SNMP object identifier that

resolves to a particular instance of an MIB object.

interval — The interval in seconds over which the data is

sampled and compared with the rising and falling

thresholds. (Range: 1–4294967295)

rising-threshold

value — Rising threshold value. (Range:

0–4294967295)

rising-threshold

value — Falling threshold value.

(Range: 0–4294967295)

• event-number — The index of the event that is used

when a rising or falling threshold is crossed. (Range: 1-

65535)

delta — The sampling method for the selected variable

and calculating the value to be compared against the

thresholds. If the method is delta, the selected variable

value at the last sample is subtracted from the current

value, and the difference compared with the thresholds.

absolute — The sampling method for the selected

variable and calculating the value to be compared against

the thresholds. If the method is absolute, the value of the

selected variable is compared directly with the thresholds

at the end of the sampling interval.

startup

direction — The type of startup alarm, which can

be rising, falling, or rising-falling.

owner

string — Enter a name that specifies who

configured this alarm.

interface

interface

Enter Interface Configuration mode for the specified port

or LAG.

Command

Purpose

Advertising