Dell POWEREDGE M1000E User Manual

Page 789

Advertising
background image

Configuring Connectivity Fault Management

789

2 Configure port 1/0/5 as an MEP for service VLAN 200 so that the port can

exchange CFM PDUs with its counterpart MEPs on the customer

network. The port is first configured as a MEP with MEP ID 20 on domain

level 6 for VLAN 200. Then the port is enabled and activated as a MEP.

console(config)#interface gigabitethernet 1/0/5

console(config-if-Gi1/0/5)#ethernet cfm mep level 6

direction down mpid 20 vlan 200

console(config-if-Gi1/0/5)#ethernet cfm mep

enabled level 6 vlan 200 mpid 20

console(config-if-Gi1/0/5)#ethernet cfm mep active

level 6 vlan 200 mpid 20

console(config-if-Gi1/0/5)#exit

3 On an intermediate switch, configure the MIP for the customer domain

and enable CFM services on the CustDom domain to include local

network devices.

Advertising