Configuring Connectivity Fault Management

Dot1ag Configuration Example

In the following example, the switch at the customer site is part of a Metro

Ethernet network that is bridged to remote sites through a provider network.

A service VLAN (SVID 200) identifies a particular set of customer traffic on

the provider network.

Figure 26-14. Dot1ag Configuration for a Metro Ethernet Customer Network

To configure the switch:

1 Enable CFM globally on the switch, and then create a level-6 management

domain named CustDom for end-to-end CFM on the Metro Ethernet

network. VLAN 200 is associated with this domain.

console#config

console(config)#ethernet cfm enable

console(config)#ethernet cfm domain CustDom level 6

console(config-cfm-mdomain)#service vlan vlan 200

console(config-cfm-mdomain)#exit

Customer Domain Level = 6

Provider Domain Level = 2

SVLAN SVID = 200

Operator Domain Level = 0

Port 1/0/5, MEP ID = 20

MIPS for Customer Domain

Level 6

MEPS for Customer Domain

Level 6