Configuring Dot1ag (CLI)

This section provides information about the commands you use to configure

Dot1ag settings on the switch. For more information about the commands,

see the

PowerConnect M6220/M6348/M8024/M8024-k CLI Reference Guide

at

support.dell.com/manuals

.

Configuring Dot1ag Global Settings and Creating Domains

Beginning in Privileged Exec mode, use the following commands to configure

CFM settings and to view global status and domain information.

CLI Command

Description

configure

Enter global configuration mode.

ethernet cfm enable

Enables connectivity fault management services.

ethernet cfm mep archive-

hold-time

time

Set the time interval (range: 1–65535 seconds) after

which inactive RMEPs are removed.

ethernet cfm cc level

level vlan

vlan-id interval {1 | 10 | 60 |

600}

Configure the Continuity Check Message (CCM)

transmit interval for the specified VLAN.

ethernet cfm domain

name

level

level

Create a maintenance domain (MD) by assigning a

name and level (0–7), and enter Maintenance

Domain Config mode for that MD.

service

name vlan vlan-id

Create a maintenance association (MA) within the

current MD by associating it with a VLAN and

naming the association (as a service instance).

exit

Exit to privileged Exec Mode

show ethernet cfm domain

brief

Display the configured parameters in the

Maintenance Domain.