Configuring Connectivity Fault Management

Configuring MEP Information

Beginning in Privileged Exec mode, use the following commands to configure

the mode and view related settings.

CLI Command

Description

configure

Enter global configuration mode.

interface

interface

Enter Interface Config mode for the specified

interface, where

interface is replaced by

gigabitethernet

unit/slot/port, or tengigabitethernet

unit/slot/port.

ethernet cfm mep enable level

level vlan vlan-id mpid mep-id

Define the port as a maintenance endpoint (MEP)

and associate it with an SVLAN in a domain. When

the MEP is enabled, it will generate CCM messages.

ethernet cfm mep level

level

direction {up | down} mpid

mep-id vlan vlan-id

Enable a MEP at the specified level and direction.

ethernet cfm mep active

Set the administrative state of the MEP to active.

ethernet cfm mip level

level

Create a MIP at the specified level on the interface.

exit

Exit to privileged Exec Mode

show ethernet cfm

maintenance–points

Add the keywords local domain, local interface,

local level, remote domain, or remote level to show

information on local or remote endpoints.

show ethernet cfm statistics

Display statistics per MEP.