(8) Initializing settings

Message communication initializes the settings for the specified program number of
a measuring instrument connected to the CB-EP100.
Service code 50H is used.
The following settings are required to use this object.

• Service code

• Class ID

• Instance ID

• Service Data

• Commands

• Response (when successful)

• Response (when failed)

Item

Description

Data Example

Service code

Specify "initialize settings (50H)" (fixed value).

50H

Class ID

CB Object (6BH) is specified (fixed value).

6BH

Instance ID

01H becomes a fixed value.

01H

Attribute ID

There is no data.

-

Service data

Specify the number of the program to initialize (00H to
0FH).

00000000H or

00000001H

Item

Description

Data Example

General status

Message communication returns status (00H) to notify
normal termination.

00H

Service response data

There is no service response data.

-

Item

Description

Data Example

General status

Message communication returns a general status.

05H

Additional status

Returns the additional status.

-

Service response data

There is no service response data.

-