KEYENCE CB-EP100 User Manual

Page 46

Advertising
background image

- EtherNet/IP Network Unit CB-EP100 User’s Manual (LJ-V7000 Edition) -

3-3 Cyclic communication

3-22

3

Communi

cat

in

g wit

h the

L

J

-V700

0 Ser

ies

Parameter List

Item

Description

Error clear request

„ ON: When error status is ON, the error is cleared.
* If clearing the error does not address the cause of the error, error status will

again go on and the error code will appear again.

* If a number of errors have occurred, all errors that can be cleared are

cleared. If any remaining errors that have not been cleared, the error codes
of the errors are output.

„ OFF: error clear completion/error clear completion failure is turned OFF.

Timing request
OUTn (n: 1 - 16)

„ ON: Changes states (ON or OFF) that specifies timing.
„ OFF: Timing completed/timing failure is turned OFF.

Auto-zero request
OUTn (n: 1 - 16)

„ ON: Changes states (ON or OFF) that specifies auto-zero..
„ OFF: Auto-zero completion/auto-zero failure has been turned off.

Reset request
OUTn (n: 1 - 16)

„ ON: Reset starts.
„ OFF: Reset completion/reset failure has been turned off.

Trigger request

„ ON: External trigger is issued.
„ OFF: External trigger completion/external trigger failure has been turned off.

Batch start request

„ ON: Batch start begins.
„ OFF: Batch start completion/batch start failure has been turned off.

Batch end request

„ ON: Batch end issued
„ OFF: Batch end completion/batch end failure has been turned off.

Storage start
request

„ ON: Storage start begins.
„ OFF: Storage start completion/storage start failure has been turned off.

Storage stop
request

„ ON: Storage stop begins.
„ OFF: Storage stop completion/storage stop failure has been turned off.

Memory clear
request

„ ON: Clears internal memory.
„ OFF: Memory clear completion/memory clear failure has been turned.

Timing
ON/OFF specified
OUTn
(n: 1 - 16)

Specifies how timing status should be changed when a timing request is made.
„ ON: Timing is ON
„ OFF: Timing is OFF

Auto-zero
ON/OFF specified
OUTn
(n: 1 - 16)

Specifies how auto-zero status should be changed when an auto-zero request
is made.
„ ON: Auto-zero is ON
„ OFF: Auto-zero is OFF

Program switch
request

„ ON: Switches the current program to the program with the specified number.
„ OFF: Program switch completion/program switch failure has been turned off.

Program number
specification

Specifies the number of the program that will be started when a program switch
is requested.

Advertising