- EtherNet/IP Network Unit CB-EP100 User’s Manual (LJ-V7000 Edition) -

2-3

Wiring

The CB-EP100 uses the power supplied to measuring instrument, so there is no
power cable wiring. This section describes the wiring of communication cables used
by the CB-EP100.

Use the following procedures to connect the CB-EP100 to the communication cable
required for EtherNet/IP communication.

„

Usable cable

Usable cables depend on whether the system is configured with 10BASE-T or
100BASE-TX.

Structuring a 10BASE-T system

When the system is configured
with 10BASE-T, use a Category
3 or higher shielded twisted-pair
(STP) cable or an unshielded
twisted-pair (UTP) cable.

Building a 100BASE-TX network or better 5e

Use STP or UTP cable category 5e or better to configure a network using
100BASE-TX. Do not use a Category 3 or Category 4 cable.

• Use an STP/UTP straight cable when connecting the CB-EP100 to an

Ethernet switch.

• Use a STP/UTP cross cable when directly connecting the CB-EP100 to

a PC or PLC.

• Do not use the STP/UTP cross cable incorrectly because it is difficult to

distinguish this cable from the STP/UTP straight cable in appearance.

• Use of 1000BASE-T Ethernet cable will not make it possible to configure

a 1000BASE-T network.

Connecting a communication cable

STP/UTP cable

Point