5-5 Objects for use with the CB-EP100

5-11

Identity Object

5

Ap
pe
ndi

x

- EtherNet/IP Network Unit CB-EP100 User’s Manual (LJ-V7000 Edition) -

Reference 1) Details of status (16 bits)

Bit

Name

Description

0

Owned

ON: This bit is set to ON when one or more Class1 or Class3
connections are established.

1

Reserved

Always OFF.

2

Reserved

Always ON.

3

Reserved

Always OFF.

4 to 7

Extended Device
Status

Bits 4 to 7 are set according to the CB-EP100 status as
follows:
0101 (1): A major fault has occurred.
0010 (2): The CB-EP100 is not (1) and one or more

connections have timed out.

0011 (3): The CB-EP100 is neither (1) nor (2) and no

connection is established.

0110 (4): The CB-EP100 is not (1), (2), or (3) and there is one

or more RUN status connections.

0111:

The CB-EP100 is in a status other than (1) to (4).

8

Minor Recoverable
Fault

Always OFF.

9

Minor
Unrecoverable Fault

Always OFF.

10

Major Recoverable
Fault

ON: This bit is set to ON when a recoverable unit error occurs.
The red MS LED flashes.

11

Major
Unrecoverable Fault

ON: This bit is set to ON when an unrecoverable unit error
(internal device error, etc.) occurs.
The red MS LED lights up.

12 to 15

Reserved

Always OFF.