3-4 Message Communication
3-71
3
Communi
cat
in
g wit
h the
L
J
-V700
0 Ser
ies
- EtherNet/IP Network Unit CB-EP100 User’s Manual (LJ-V7000 Edition) -
Instance ID = 200 to 215
The OUT setting of the setting write area for the program number indicated by the
last two digits of the instance ID can be referred to and updated during operation.
Data written to this instance ID is stored without being immediately reflected in
measurement, and is reflected in the settings used for measurement by using the
service code 4EH of instance ID = 1. Reading is the same as instance ID = 100 to
115, but if the setting values have been changed to some extent, refer to the new
values.
Service code
(hexadecimal)
Attribute ID
(hexadecimal)
Name
Description and service data
Attribute
Data
type
64H
-
98FH
Reserved
W:10H
R:0EH
990H
-
99EH
OUT1 setting
Refer to the same address as instance
ID = 1
R/W
DINT
99FH
-
9AFH
Reserved
W:10H
R:0EH
9B0H
-
9BEH
OUT2 setting
Refer to the same address as instance
ID = 1
R/W
DINT
9BFH
-
9CFH
Reserved
W:10H
R:0EH
9D0H
-
9DEH
OUT3 setting
Refer to the same address as instance
ID = 1
R/W
DINT
9DFH
-
9EFH
Reserved
W:10H
R:0EH
9F0H
-
9FEH
OUT4 setting
Refer to the same address as instance
ID = 1
R/W
DINT
9FFH
-
A0FH
Reserved
W:10H
R:0EH
A10H
-
A1EH
OUT5 setting
Refer to the same address as instance
ID = 1
R/W
DINT
A1FH
-
A2FH
Reserved
W:10H
R:0EH
A30H
-
A3EH
OUT6 setting
Refer to the same address as instance
ID = 1
R/W
DINT
A3FH
-
A4FH
Reserved
W:10H
R:0EH
A50H
-
A5EH
OUT7 setting
Refer to the same address as instance
ID = 1
R/W
DINT
A5FH
-
A6FH
Reserved
W:10H
R:0EH
A70H
-
A7EH
OUT8 setting
Refer to the same address as instance
ID = 1
R/W
DINT