- EtherNet/IP Network Unit CB-EP100 User’s Manual (LJ-V7000 Edition) -

3-3 Cyclic communication

3-18

3

Communi

cat

in

g wit

h the

L

J

-V700

0 Ser

ies

OUT measurement
value
OUTn (n: 1 - 16)

Stores all OUT measurement values (32-bit DINT type

Page 3-40).

Measurement values are output in the following units depending on
measurement mode.
„ Length (height, width, etc.): 0.01 m units
Example: 1234560

⇒12345.60

m

„ Cross-sectional area: 0.00001mm

2

units

Example: 123456

⇒ 1.23456mm

2

„ Angle: 0.001 units
Example: 12340

⇒ 12.340

* The OUT measurement value results in an alarm in the following cases.

• When measurement mode is "No measurement"

• When operation mode is "High-speed mode"

* When the OUT measurement value status is judgment standby, 80000001H

is returned.

* When the OUT measurement value status is alarm, 80000000H is returned.
* For details on how to obtain the current value, refer to page 3-24.

OUT measurement
value update count
OUTn (n: 1 - 16)

Each time measurement values are output and updated, the count is
incremented by 1.
The count range is 0 to 65535 and 65535 is incremented to 0.

OUT measurement
value display unit
OUTn (n: 1 - 16)

Stores all OUT measurement value display units.

In the following cases, the display unit for OUT measurement values becomes 0
(initial value).

• When measurement mode is "No measurement"

• When operation mode is "high-speed mode"

Number of storage
data points

Stores the current number of storage data points (32-bit DINT type).

Item

Description

Display unit code

Minimum display unit setting

0

1mm

1

0.1mm

2

0.01mm

3

0.001mm

4

1μm

5

0.1μm

100

1mm

2

101

0.1mm

2

102

0.01mm

2

103

0.001mm

2

104

0.0001mm

2

105

0.00001mm

2

200

1deg

201

0.1deg

202

0.01deg