Troubleshooting

The indicator LEDs on the CB-EP100 can be used to determine the causes of errors.

„

Link/activity indicator (LINK/ACT)

This indicator indicates whether the CB-EP100 is communicating correctly.

„

Module status indicator (MS)

This indicator indicates whether the CB-EP100 is operating normally.

Link/activity indicator

Module status indicator

Network status indicator

LED Status

Communication unit status

Corrective Action

Green

Solid

Link Correctly established.

-

Flashing

Link correctly established, and
exchanging data.

-

Off

The CB-EP100 is not supplied with
power.

• Check if the power supply is correctly

connected.

• Check if the CB-EP100 is correctly connected to

the measurement instrument.

Link is not established.

• Check if the power supply of the

connected device or Ethernet switch is
correctly connected.

• Check if the cable is correctly connected.

LED Status

Communication unit status

Corrective Action

Green Solid

The CB-EP100 is operating
normally.

-

Red

Solid

An error may have occurred in the
CB-EP100.

Contact your nearest KEYENCE office.

Flashing

The connected controller is in error
status.

A connected measuring instrument is in an
error state. Clear the error for measuring
instrument.

A recoverable error may have
occurred in the CB-EP100.

Check if the IP address is duplicated.

Off

The CB-EP100 is not supplied with
power.

• Check if the power supply is correctly

connected.

• Check if the CB-EP100 is correctly

connected to the measuring instrument.