KEYENCE CB-EP100 User Manual

Page 133

Advertising
background image

5-5 Objects for use with the CB-EP100

5-17

Connection Manager Object

5

Ap
pe
ndi

x

- EtherNet/IP Network Unit CB-EP100 User’s Manual (LJ-V7000 Edition) -

*1

Forward_Open is successful if the size trying to be opened is less than the size
defined in the scan list. If this error occurs, an extended status is added and
the data size of the tag defined in the second extended status is returned.

*2

RPI is set in increments of 500

s. If a value that cannot be divided by 500

s

is designated, an RPI rounded to the nearest 500 s is set.

Forward_
Open

01H

0315H

• Connection Size in the ForwardOpen network connection

parameter is 0.

• Connection Path in ForwardOpen does not include

ConnectionPoint.

• In Connection Path class ID in ForwardOpen, a value other than

04H was set for cyclic or a value other than 02H was set for
Class 3.

• In Class3, a value other than 1 is set as the instance ID of

Connection Path of ForwardOpen.

• There is a setting unique for the product data segment.
• In cyclic communication, an invalid Connection Point is

designated in the send direction of Connection Path in
ForwardOpen.

• In cyclic communication, a value other than 2 is designated as

the Connection Size network connection parameter in the send
direction of ForwardOpen.

• In cyclic communication, an invalid Connection Point is

designated in the receive direction of Connection Path in
ForwardOpen.

0323H

An unsupported measuring instrument is connected.

04C2H

A product-unique setting is incorrect.

0640H-067FH

The corresponding device is not connected or an error
occurred during communication with a measuring instrument.

06C0H-06FFH

The number of occupied slots is different

0700H-073FH

When "Check Model Match" is selected for compatibility
check, the ProductCode does not match.

0740H-077FH

When "Check Model Match" is selected for compatibility
check, the major revision or minor revision does not match
match.

0780H-07BFH

When "Check Series" is selected as compatibility check, the
series code does not match.

07C0H-07FFH

When "Check Series" is selected as compatibility check, the
actual series version is lower than the setting.

02H

-

The maximum number of connections has already been
owned.

04H

-

The attribute ID is already designated.

05H

-

The designated instance ID does not exist.

13H

-

The length of send data is too short.

15H

-

The length of send data is too large.

Others

08H

-

The designated service is not supported.

Name

General

Status

Additional

(Extended)

Status

Description