- EtherNet/IP Network Unit CB-EP100 User’s Manual (LJ-V7000 Edition) -

„

Monitor Data (156 Words (312 Bytes)) Assembly Instance (Instance ID): 64H

This is the device map for the monitor data to be assigned to the IN area.
For details on each parameter, refer to

"Parameter List" (Page 3-15).

Name

Address

(Byte)

bit7

bit6

bit5

bit4

bit3

bit2

bit1

bit0

System

Status

0

Reserved for system

Started

up

CB-EP100

Error Status

Error Status

1

Reserved for system

Saving

Reserved

for system

LJ-V

Error status

Measuring
instrument

status

2

Reserved for system

REMOTE

LASER_OFF

3

Reserved for system

MEMORY

_FULL

Valid

status

4

Valid status

OUT8

Valid status

OUT7

Valid status

OUT6

Valid status

OUT5

Valid status

OUT4

Valid status

OUT3

Valid status

OUT2

Valid status

OUT1

5

Valid status

OUT16

Valid status

OUT15

Valid status

OUT14

Valid status

OUT13

Valid status

OUT12

Valid status

OUT11

Valid status

OUT10

Valid status

OUT9

Judgment

standby

status

6

Judgment

standby

status

OUT8

Judgment

standby

status

OUT7

Judgment

standby

status

OUT6

Judgment

standby

status

OUT5

Judgment

standby

status

OUT4

Judgment

standby

status

OUT3

Judgment

standby

status

OUT2

Judgment

standby

status

OUT1

7

Judgment

standby

status

OUT16

Judgment

standby

status

OUT15

Judgment

standby

status

OUT14

Judgment

standby

status

OUT13

Judgment

standby

status

OUT12

Judgment

standby

status

OUT11

Judgment

standby

status

OUT10

Judgment

standby

status

OUT9

Alarm
status

8

Alarm
status
OUT8

Alarm
status
OUT7

Alarm
status
OUT6

Alarm
status
OUT5

Alarm
status
OUT4

Alarm
status
OUT3

Alarm
status
OUT2

Alarm
status
OUT1

9

Alarm
status

OUT16

Alarm
status

OUT15

Alarm
status

OUT14

Alarm
status

OUT13

Alarm
status

OUT12

Alarm
status

OUT11

Alarm
status

OUT10

Alarm
status
OUT9

Reserved

for system

10

-

15

Reserved for system

Judgment

output (HI)

16

HI

OUT8

HI

OUT7

HI

OUT6

HI

OUT5

HI

OUT4

HI

OUT3

HI

OUT2

HI

OUT1

17

HI

OUT16

HI

OUT15

HI

OUT14

HI

OUT13

HI

OUT12

HI

OUT11

HI

OUT10

HI

OUT9

Judgment

output

(LO)

18

LO

OUT8

LO

OUT7

LO

OUT6

LO

OUT5

LO

OUT4

LO

OUT3

LO

OUT2

LO

OUT1

19

LO

OUT16

LO

OUT15

LO

OUT14

LO

OUT13

LO

OUT12

LO

OUT11

LO

OUT10

LO

OUT9

Judgment

output

(GO)

20

GO

OUT8

GO

OUT7

GO

OUT6

GO

OUT5

GO

OUT4

GO

OUT3

GO

OUT2

GO

OUT1

21

GO

OUT16

GO

OUT15

GO

OUT14

GO

OUT13

GO

OUT12

GO

OUT11

GO

OUT10

GO

OUT9

Reserved

for system

22

-

33

Reserved for system

Timing

status

34

Timing

status

OUT8

Timing

status
OUT7

Timing

status

OUT6

Timing

status

OUT5

Timing

status

OUT4

Timing

status

OUT3

Timing

status
OUT2

Timing

status

OUT1

35

Timing

status

OUT16

Timing

status

OUT15

Timing

status

OUT14

Timing

status

OUT13

Timing

status

OUT12

Timing

status

OUT11

Timing

status

OUT10

Timing

status

OUT9