5-5 Objects for use with the CB-EP100

5-12

Identity Object

5

Ap
pe
ndi

x

- EtherNet/IP Network Unit CB-EP100 User’s Manual (LJ-V7000 Edition) -

Reset service
The Reset service is a CIP standard function used to emulate the operation of turning
power on as closely as possible. When it accepts this service, the CB-EP100 stops
each function, interrupts communication, and reads the settings again. The Reset
service is used as a restart request for reflecting changed parameters (e.g., IP
address, etc.).
Execute this service by designating 01H as the Instance ID of the Identity object.

• The commands received during Reset processing may be discarded.
• The response for the Reset service is returned before the CB-EP100

starts reset processing.

„

List of general and additional statuses returned to each service

Service Code

Service Name

Service Data (1 Byte)

05H

Reset

00H: Emulates power reset. (Initial value)
01H: Restores the default settings and emulates power reset.

For details on the default settings, refer to

"Default

Settings" (Page 5-5).
• If the CB-EP100 receives the Reset service when 02H or higher is

set, 03H (Invalid parameter value) will be returned as the CIP
error code.

Point

Service

General

Status

Additional

(Extended)

Status

Description

Get_Attributes_
All

00H

-

The service has ended normally.

05H

-

The designated instance ID does not exist.

Reset

00H

-

The service has ended normally.

03H

-

The designated reset method is incorrect.

05H

-

The designated instance ID does not exist.

Get_Attribute_
Single

00H

-

The service has ended normally.

05H

-

The designated instance ID does not exist.

14H

-

The designated attribute ID does not exist.

Others

08H

-

The designated service is not supported.