- EtherNet/IP Network Unit CB-EP100 User’s Manual (LJ-V7000 Edition) -

3-4 Message Communication

3-62

3

Communi

cat

in

g wit

h the

L

J

-V700

0 Ser

ies

0EH

AD0H

[OUT11 setting]
measurement
value hold count

Specifies a measurement value hold
count (0 - 999).

R

DINT

AD1H

[OUT11 setting]
measurement
value filter

0: OFF
1: Moving average
2: Low-pass filter
3: High-pass filter

AD2H

[OUT11 setting]
measurement
value filter details

Moving average mode

⇒ 0: 4 times,

1: 16 times, 2: 64 times, 3: 256 times,
4: 1024 times, 5: 4096 times
High-pass, low-pass

⇒ 0: 0.1 Hz,

1: 0.3 Hz, 2: 1 Hz, 3: 3 Hz, 4: 10 Hz,
5: 30 Hz, 6: 100 Hz, 7: 300 Hz,
8: 1000 Hz

AD3H

[OUT11 setting]
hold modes

0: Normal, 1: Peak hold, 2: Bottom
hold, 3: Peak-to-peak hold, 4: Aver-
age hold, 5: Sample hold, 6: Peak, 7:
Bottom, 8: Peak-to-peak, 9: Average
(0 to 5 can be set when batch mea-
surement is OFF, and 6 to 9 can be
set when batch measurement is ON.)

AD4H

[OUT11 setting]
scaling measure-
ment value 1

Set each measurement value with the
following units depending on the mea-
surement mode.

„ Length (height, width, etc.):

0.01

m units

Example:

1234560

⇒ 12345.60m

„ Cross-sectional area:

0.00001mm

2

units

Example:
123456

⇒ 1.23456mm

2

„ Angle: 0.001 units

Example: 12340

⇒ 12.340

AD5H

[OUT11 setting]
scaling display
value 1

AD6H

[OUT11 setting]
scaling measure-
ment value 2

AD7H

[OUT11 setting]
scaling display
value 2

AD8H

[OUT11 setting]
offset

AD9H

[OUT11 setting]
Upper tolerance limit

ADAH

[OUT11 setting]
Lower tolerance limit

ADBH

[OUT11 setting]
Tolerance hysteresis

ADCH

[OUT11 setting]
zero reference value

ADDH

[OUT11 setting]
Zero terminal

0 None, 1: ZERO1, 2: ZERO2

ADEH

[OUT11 setting]
TIMING/RESET
terminal

0: None, 1: TIMNG1/RESET1,
2: TIMING2/RESET2

ADFH

-

AEFH

Reserved

Service

code

(hexadecimal)

Attribute

ID

(hexadecimal)

Name

Description and service data

Attribute

Data type