KEYENCE CB-EP100 User Manual

Page 41

Advertising
background image

3-3 Cyclic communication

3-17

3

Communi

cat

in

g wit

h the

L

J

-V700

0 Ser

ies

- EtherNet/IP Network Unit CB-EP100 User’s Manual (LJ-V7000 Edition) -

Memory clear
completion

Indicates whether the memory clear request has been completed (when
successful).
„ ON: Memory clear request has been completed (when successful)
„ OFF: Memory clear request has not been completed (when not successful)

Timing failure
OUTn (n: 1 - 16)

Indicates whether the timing input request for measurement values has failed.
„ ON: Timing input request has failed
„ OFF: Timing input request has not failed

Auto-zero failure
OUTn (n: 1 - 16)

Indicates whether the auto-zero input request for OUT measurement values has
failed.
„ ON: Auto-zero input request has failed
„ OFF: Auto-zero input request has failed

Reset failure
OUTn (n: 1 - 16)

Indicates whether the reset input request for OUT measurement values has
failed.
„ ON: Reset input request has failed.
„ OFF: Reset input request has not failed.

Trigger failure

Indicates whether the external trigger request has failed.
„ ON: External trigger request has failed.
„ OFF: External trigger request has not failed.

Batch start failure

Indicates whether the batch start request has failed..
„ ON: Batch start request has failed.
„ OFF: Batch start request has not failed.

Batch end failure

Indicates whether the batch end request has failed.
„ ON: Batch end request has failed.
„ OFF: Batch end request has not failed.

Storage start
failure.

Indicates whether the storage start request has failed.
„ ON: Storage start request has failed.
„ OFF: Storage start request has not failed.

Storage stop
completion

Indicates whether the storage end request has failed.
„ ON: Storage end request has failed.
„ OFF: Storage end request has not failed.

Error clear failure

Indicates whether the error clear request has failed.
„ ON: Error clear request has failed.
„ OFF: Error clear request has not failed.

Memory clear
failure

Indicates whether the memory clear request has failed.
„ ON: Memory clear request has failed.
„ OFF: Memory clear request has not failed.

Program switch
completion

Indicates whether a program switch has been completed (when successful).
„ ON: Program switch request has been completed (when successful).
„ OFF: Program switch request has not been completed (when not successful).

Program switch
failure

Indicates whether a program switch has failed.
„ ON: Program switch request has failed
„ OFF: Program switch request has not failed

Error code

When "Error status" is ON, the error code is stored. When no error has occurred,
0000H is stored.
The error code stored the code of the first output error, but this data is not
overwritten when subsequent errors occur.

"Error code list" (Page 3-19)

Current program
number

Stores current program number,

Item

Description

Advertising