3-4 Message Communication

3-41

3

Communi

cat

in

g wit

h the

L

J

-V700

0 Ser

ies

- EtherNet/IP Network Unit CB-EP100 User’s Manual (LJ-V7000 Edition) -

Services

*1 Cannot specify the CB-EP100 (instance ID = 00H).

Service

Code

Service Name

Description

0EH

Read setting values

Reads setting values values from the CB-EP100 or from
measuring instrument connected to it. For examples, refer to
3-74.

10H

Writes setting values

Writes setting values values from the CB-EP100 or from
measuring instrument connected to it. For examples, refer to
page 3-75.

4BH

*1

Switching the

programs

Switches the program number of measuring instrument
connected to the CB-EP100 to program number specified in
the service data.

4CH

Clear errors

Clear the errors of the both the CB-EP100 and measuring
instrument.

4DH

*1

Control input

indication

Sets trigger and auto-zero and other control input of an
attribute ID to the status indicated in the service data.

4EH

*1

Request to reflect

setting write area

Reflects the settings of the setting write area up to the
specified hierarchy level.

4FH

*1

Update of setting

write area

Updates the settings of the setting write area with the settings
of the specified hierarchy level.

50H

*1

Initialization of

settings

Initializes the setting values for the program number
designated in the service data.

57H

*1

Confirm profile data

Confirms the profile data and copies it to the profile data area.

58H

*1

Set date and time

The date and time in the controller are set to match the date
and time designated in the service data.

59H

*1

Acquires date and

time

Acquires the date and time of the measuring instrument.

5FH

*1

Initializes all settings

Resets the setting area of the CB-EP100 and setting values
connected to the CB-EP100 to their default values.