KEYENCE CB-EP100 User Manual
Page 65
3-4 Message Communication
3-41
3
Communi
cat
in
g wit
h the
L
J
-V700
0 Ser
ies
- EtherNet/IP Network Unit CB-EP100 User’s Manual (LJ-V7000 Edition) -
Services
*1 Cannot specify the CB-EP100 (instance ID = 00H).
Service
Code
Service Name
Description
0EH
Read setting values
Reads setting values values from the CB-EP100 or from
measuring instrument connected to it. For examples, refer to
3-74.
10H
Writes setting values
Writes setting values values from the CB-EP100 or from
measuring instrument connected to it. For examples, refer to
page 3-75.
4BH
*1
Switching the
programs
Switches the program number of measuring instrument
connected to the CB-EP100 to program number specified in
the service data.
4CH
Clear errors
Clear the errors of the both the CB-EP100 and measuring
instrument.
4DH
*1
Control input
indication
Sets trigger and auto-zero and other control input of an
attribute ID to the status indicated in the service data.
4EH
*1
Request to reflect
setting write area
Reflects the settings of the setting write area up to the
specified hierarchy level.
4FH
*1
Update of setting
write area
Updates the settings of the setting write area with the settings
of the specified hierarchy level.
50H
*1
Initialization of
settings
Initializes the setting values for the program number
designated in the service data.
57H
*1
Confirm profile data
Confirms the profile data and copies it to the profile data area.
58H
*1
Set date and time
The date and time in the controller are set to match the date
and time designated in the service data.
59H
*1
Acquires date and
time
Acquires the date and time of the measuring instrument.
5FH
*1
Initializes all settings
Resets the setting area of the CB-EP100 and setting values
connected to the CB-EP100 to their default values.