C100 and C150 SNMP MIB

6/15/99

Verilink C100 and C150 T1/FT1 CSU/DSUs

D-3

DS1 Near End
Group

The DS1 Near End Group consists of four tables:

DS1 Configuration (ds1 6)

DS1 Current (ds1 7)

DS1 Interval (dsl 8)

DS1 Total (dsl 9)

DS1 Configuration
Table (x = 6)

The DS1 Configuration Table consists of 13 entries.

dsx1ConfigEntry 1 through 4 and 10 are read-only

dsx1ConfigEntry 5 through 9 and 11 through 13 are read-write accessible.

dsx1LineIndex Object (dsx1ConfigEntry 1)

This read-only object is the identifier of a DS1 Interface on a managed
device. If there is an ifEntry that is directly associated with this and
only this DS1 interface, it should have the same value as ifIndex
Otherwise, the value exceeds ifNumber, and is a unique identifie
following this rule: inside interfaces (e.g., equipment side) with even
numbers and outside interfaces (e.g., network side) with odd numbers.

dsx1IfIndex Object (dsx1ConfigEntry 2)

The value for this read-only object is equal to the value of ifIndex from
the Interfaces table of MIB II (RFC 1406).

dsx1TimeElapsed Object (dsx1ConfigEntry 3)

The value for this read-only object is the number of seconds that have
elapsed since the beginning of the current error-measurement period.

dsx1ValidIntervals Object (dsx1ConfigEntry 4)

The value for this read-only object is the number of previous intervals
for which valid data was collected. The value will be 96 unless the
interface was brought on-line within the last 24 hours, in which case
the value will be the number of complete 15 minute intervals since the
interface has been online.