sysTiming Object (sysConfigEntry 4)

This variable defines the system timing options. The following values
are supported:

Network

DSX1 - C150 only

Internal

Channel

Network (loop timing)

DSX1 (through timing) - C150 only

Internal (local timing)

Channel (through timing)

Channel
Configuration

Group

(chnConfig x=2)

The chnConfig Group consists of six read-write variables:

chnInterface (y = 1)

chnRxsignal (y = 2)

chnData (y = 3)

chnClock (y = 4)

chnTiming (y = 5)

chnBandwidth (y =6)

chnInterface Object (chnConfigEntry 1)

This variable is used to select the interface on the Synchronous
Channel. The following values are supported:

RS530

RS232

V.35

chnRxsignal Object (chnConfigEntry 2)

This variable selects Switched or Continuous Carrier Control. This
works in conjunction with the Request-to-Send (RTS) control signal,
the Carrier Detect (CD or RLSD) control signal and the 56000/64000
DS0 bandwidth selection. The following values are supported:

Continuous

Switched