Switches – Verilink C100 (880-502893-001) Product Manual User Manual

Page 91

Advertising
background image

C100 and C150 Specifications

6/15/99

Verilink C100 and C150 T1/FT1 CSU/DSU

A-3

BPV ALARM

Lit when Bipolar Violation received from
Network.

DENSITY ALARM

Lit when Ones Density Violation is detected.

YELLOW ALARM

Lit when YELLOW alarm received from
Network.

BLUE ALARM

Lit when BLUE alarm received from
Network.

NI LOCK

Green when unit is frame-locked to
Network. Red when Out Of Frame (OOF).

NI TX DATA

Lit when NI TX DATA is spacing.

NI RX DATA

Lit when NI RX DATA is spacing.

Local Network (NI)

Lit when Local Network loop is detected.

Local CI Chan

Lit when Local CI Channel loop is detected.

Local Payload

Lit when Payload loop is detected.

Remote Network (NI)

Lit when Remote Network loop is selected.

Remote CI Chan

Lit when Remote CI Channel loop is
selected.

Test Pattern

Green when the Test Pattern is good. Red
when the Test Pattern is not good.

C150 only

CI DSX1 TX DATA

Lit when DSX1 TX DATA is spacing.

CI DSX1 RX DATA

Lit when DSX1 RX DATA is spacing.

CI DSX1 LOCK

Green when unit is frame-locked to DSX-1
channel. Red when DSX1 channel is Out Of
Frame (OOF).

Local CI DSX-1 Chan

Lit when Local CI DSX-1 Channel loop is
detected.

Remote CI DSX-1 Chan

Lit when Remote CI DSX-1 Channel loop is
selected.

Switches

Select

Momentary Pushbutton

Start

Momentary Pushbutton

Advertising