Verilink C100 (880-502893-001) Product Manual User Manual

Page 123

Advertising
background image

C100 and C150 SNMP MIB

6/15/99

Verilink C100 and C150 T1/FT1 CSU/DSUs

D-9

dsx1IntervalNumber Object - (dsx1IntervalEntry 2)

A number between 1 and 96, where 1 is the most recently completed 15
minute interval and 96 is the least recently completed 15 minutes
interval (assuming that all 96 intervals are valid).

dsx1IntervalESs Object - (dsx1IntervalEntry 3)

The number of Errored Seconds encountered by a DS1 interface in one
of the previous 96, individual 15 minute, intervals.

dsx1IntervalSESs Object - (dsx1IntervalEntry 4)

The number of Severely Errored Seconds encountered by a DS1
interface in one of the previous 96, individual 15 minute, intervals

dsx1IntervalSEFSs Object - (dsx1IntervalEntry5)

The number of Severely Errored Framing Seconds encountered by a
DS1 interface in one of the previous 96, individual 15 minute,
intervals.

dsx1IntervalUASs Object - (dsx1IntervalEntry 6)

The number of Unavailable Seconds encountered by a DS1 interface in
one of the previous 96, individual 15 minute, intervals.

dsx1IntervalCSSs Object - (dsx1IntervalEntry 7)

The number of Controlled Slip Seconds encountered by a DS1 interface
in one of the previous 96, individual 15 minute, intervals.

dsx1IntervalPCVs Object - (dsx1IntervalEntry 8)

The number of Path Coding Violations encountered by a DS1 interface
in one of the previous 96, individual 15 minute, intervals.

dsx1IntervalLESs Object - (dsx1IntervalEntry 9) - not supported

The number of Line Errored Seconds encountered by a DS1 interface in
one of the previous 96, individual 15 minute, intervals.