56000 or 64000, 56000 or 64000 -11, Table 3-5 – Verilink C100 (880-502893-001) Product Manual User Manual

Page 35: Number of 56000 or 64000 ds0s selected -11

Advertising
background image

Configuration Using the DIP Switches

06/17/97

C100 and C150 T1/FT1 CSU/DSU

3-11

56000 or 64000

Switch pack 4 position 4 determines whether the bandwidth of all DS-
0s to the Synchronous Channel is 56000 or 64000 bps. With position 4
Off all DS-0s to the Synchronous Channel are 56000 bps. To calculate
the Channel speed, multiply 56000 times the number of DS0s going to
the Channel. If 4 DS-0s were selected to go to the Synchronous
Channel, the Channel speed would be 224000 bps.

Setting position 4 to On gives 64000 bps to all the selected DS0s going
to the Channel. The same calculation applies when using 64000 bps.
Multiply 64000 times the selected DS-0s to calculate Channel speed.

The following chart lists all the multiples of 56000 and 64000 bps
available with the C100/C150 T-1 CSU/DSU. This option must be set
the same in both units.

Table 3-5

Number of 56000 or 64000 DS0s selected

Numbers of

Multiplied

Multiplied

DS0's selected

by 56000

by 64000

1

56000

64000

2

112000

128000

3

168000

192000

4

224000

256000

5

280000

320000

6

336000

384000

7

392000

448000

8

448000

512000

9

504000

576000

10

560000

640000

11

616000

704000

12

672000

768000

13

728000

832000

14

784000

896000

15

840000

960000

16

896000

1024000

17

952000

1088000

18

1008000

1152000

19

1064000

1216000

20

1120000

1280000

21

1176000

1344000

22

1232000

1408000

23

1288000

1472000

24

1344000

1536000

Advertising