C100 and C150 SNMP MIB

D-18

Verilink C100 and C150 T1/FT1 CSU/DSUs

6/15/99

dsx1LineLength (y = 6)

dsx1TrunkProcessing (y = 7)

dsx1Enable Object (dsx1ConfigEntry 1)

This variable is used to enable/disable the DSX1 interface. When DSX
Out, the DSX1 interface is completely disabled. When the DSX1 is not
used, the DSX1 should be disabled for proper operation of the unit.
The following values are supported:

DSXIn

DSXOut

dsx1Framing Object (dsx1ConfigEntry 2)

This variable determines the dsx1 framing format.The following
values are supported:

ESF

D4

dsx1Coding Object (dsx1ConfigEntry 3)

This variable describes the variety of Zero Code Suppression used on
the link, which in turn affects a number of its characteristics. B8ZS
refers to the use of a specified pattern of normal bits and bipola
violations which are used to replace a sequence of eight zero bits. AMI
refers to a mode wherein no zero code suppression is present and the
line encoding does not solve the problem directly. In this application,
the higher layer must provide data which meets or exceeds the pulse
density requirements. The following values are supported:

B8ZS

AMI

dsx1Loop Object (dsx1ConfigEntry 4)

This variable describes the state of the DSX1 loop (off or on). The
following values are supported:

off

on

dsx1LineStatus Object (dsx1Config Entry 5)

This variable indicates the LineStatus of the interface. It contains
loopback, failure, received alarm and transmitted alarm information.