C100 and C150 SNMP MIB

6/15/99

Verilink C100 and C150 T1/FT1 CSU/DSUs

D-5

sending a loopback termination request

dsx1SendOtherTestPattern

sending a test pattern other than those described
by this object

dsx1CircuitIdentifier Object (dsx1ConfigEntry 8)

This read-write variable contains the transmission vendor's circuit
identifier, for the purpose of facilitating troubleshooting.

dsx1LoopbackConfig Object (dsxqConfigEntry 9)

This read-write variable represents the loopback configuration of the
DS1 interface. Agents supporting read/write access should return
badValue in response to a requested loopback state that the interface
does not support. The following values are supported:

dsx1NoLoop

dsx1PayloadLoop

dsx1LineLoop

dsx1OtherLoop

The values mean:

dsx1NoLoop

Not in the loopback state. A device that is not
capable of performing a loopback on the interface
shall always return this as its value.

dsx1PayloadLoop

The received signal at this interface is looped
through the device. Typically the received signal
is looped back for re-transmission after it has
passed through the device's framing function.

dsx1LineLoop

The received signal at this interface does not go
through the device (minimum penetration) but is
looped back out.

dsx1OtherLoop

Loopbacks that are not defined here.

dsx1LineStatus Object (dsx1ConfigEntry 10)

This read-only variable indicates the Line Status of the interface. It
contains loopback, failure, received 'alarm' and transmitted 'alarm'
information.

The following notes apply: