Diagnostics and statistics, Diagnostics and statistics -5, Figure 8-5 – Verilink C100 (880-502893-001) Product Manual User Manual

Page 81: Diagnostics and statistics screen -5

Advertising
background image

Performance Monitoring with the Console Port

06/17/97

C100 and C150 T1/FT1 CSU/DSU

8-5

Diagnostics and Statistics

Figure 8-5

Diagnostics and Statistics Screen

The blinking cursor is positioned to the left of the Local NI Loop
Selection when entering the Diagnostics and Statistics screen. There
are eight fields that be changed on this screen; seven loopbacks and the
test pattern. In addition there are a variety of other statistics on this
screen.

All the loops and the test pattern work in conjunction with the front
panel and with remote loops coming from the Network. They are both
switches and indicators. If a loop is activated at the front panel, the
screen changes to show the loopback and conversely if a loop is turned
On with the console, the LED indicators on the front panel displays it.
If a loop field displays On, the loop was activated locally either by the
front panel or console. If the screen displays On-Rem, this indicates the
loop came from the Network. When using loops and test patterns, care
must be taken to insure there are no conflicts between the console, the
front panel and loops coming from the Network. In general, the last
loop activated takes priority.

The following is a description of the loopbacks, test pattern and
statistics:

29 APR 1997 VERILINK CORPORATION 14:50:45
UNIT ADDRESS 1 T-1 CSU/DSU CONSOLE
Diagnostics & Statistics
Local Loops NI Alarms 15m 24 hr CI Alarms Total
NI: Off ESF Err Event: 900 65535 ESF Err Event: 999999
DSX1: Off CRC6 Errors: 000 00000 CRC6 Errors: 000000
Chan: Off Errored Secs: 000 00000 Errored Secs: 000000
Payload: Off Unavail Secs: 236 65535 Unavail Secs: 082224
Remote Loops Sev Errd Secs: 000 00000 Sev Errd Secs: 000000
NI: Off Bur Errd Secs: 000 00000 Bur Errd Secs: 000000
DSX1: Off Loss of Frame: 000 00001 Loss of Frame: 000001
Chan: Off BiPolar Viol: 869 65047 BiPolar Viol: 999999
Test: Off Tx Bit Dens: 000 00000 Tx Bit Dens: 999999
Test Seconds: 000000 Rx Bit Dens: 900 65535 Rx Bit Dens: 999999
Secs in Err: 000000 YEL Alarm Sec: 000 00000 YEL Alarm Sec: 000000
Err Free Sec: 000000 BLU Alarm Sec: 000 00000 BLU Alarm Sec: 000000
Ctl Slip Secs: 000 00000
Status: FU000000 Val Interval: 91 Val Interval: 91
NI LEDS: TX RX * DSX1 LEDS: TX * RX * Chan LEDS: TX RX CD
OOF OOF
CURSOR FORWARD = [SPACE] CURSOR BACK = [B]
SELECT = [ENTER] RESET = [R] MAIN MENU = [ESC]