Verilink C100 (880-502893-001) Product Manual User Manual

Page 131

Advertising
background image

C100 and C150 SNMP MIB

6/15/99

Verilink C100 and C150 T1/FT1 CSU/DSUs

D-17

chnData Object (chnConfigEntry 3)

This variable determines whether data to and from the Synchronous
Channel is normal or inverted. By inverting the data, both the transmit
and receive data signals at the local Synchronous Channel are
inverted. The following values are supported:

Normal

Inverted

chnClock Object (chnConfigEntry 4)

This variable determines whether the External Transmit Clock from
the Synchronous Channel is normal or inverted. Inverted Transmit
Clock is used when the round trip delay of the Transmit Clock exceeds
one half bit time. The following values are supported:

Normal

Inverted

chnTiming Object (chnConfigEntry 5)

This variable determines whether the Internal Transmit Clock from the
T-1 CSU/DSU is provided to the Synchronous Channel or whether the
External Transmit Clock from the terminal equipment is provided to
the Synchronous Channel. The following values are supported:

Internal

External

chnBandwidth Object (chnConfig Entry 6)

This variable is used to determine whether the bandwidth of all DS0s
to the Synchronous Channel is 56000 or 64000 bps. The following
values are supported:

chn56000

chn64000

DSX1 Configuration
Group (dsx1Config
x= 3)
—C150 only—

The dsx1Config Group consists of six read-write variables and one
read-only variable:

dsx1Enable (y = 1)

dsx1Framing (y = 2)

dsx1Coding (y = 3)

dsx1Loop (y = 4)

dsx1LineStatus (y = 5) [read-only]

Advertising