Verilink C100 (880-502893-001) Product Manual User Manual

Page 133

Advertising
background image

C100 and C150 SNMP MIB

6/15/99

Verilink C100 and C150 T1/FT1 CSU/DSUs

D-19

The following notes apply:

The dsx1LineStatus is a bit map represented as a sum; therefore, it
can represent multiple failures (alarms) and a LoopbackState
simultaneously.

dsx1NoAlarm should be set if and only if no other flag is set.

If the dsx1LoopbackState bit is set, the loopback in effect can be
determined from the dsx1LoopbackConfig object.

The following values are supported:

dsx1LineLength Object (dsx1ConfigEntry 6)

This variable controls the output power of the T-1 driver on the DSX1
interface. The following values are supported:

133 ft/0dB

266 ft

399 ft

533 ft

655 ft

-7.5dB

-15dB

-22.5dB

dsx1TrunkProcessing Object (dsx1ConfigEntry 7)

This variable represents the trunk processing control. The following
values are supported:

idle

busy

1

dsx1NoAlar

No Alarm Present

2

dsx1RcvFarEndLOF

Far end LOF (a.k.a., Yellow Alarm)

4

dsx1XmtFarEndLOF

Near end sending LOF Indication

8

dsx1RcvAIS

Far end sending AIS

16

dsx1XmtAIS

Near end sending AIS

32

dsx1LossOfFrame

Near end LOF (a.k.a., Red Alarm)

64

dsx1LossOfSignal

Near end LOS

128

dsx1LoopbackState

Near end is looped

256

dsx1T16AIS

E1 TS16 AIS

512

dsx1RcvFarEndLOMF

Far end sending TS16 LOMF

1024

dsx1XmtFarEndLOMF

Near End Sending TS16 LOMF

2048

dsx1RcvTestCode

Near End detects a test code

4096

dsx1OtherFailure

Any line status not defined here

Advertising
This manual is related to the following products: