6 digital operator copy function faults, Digital operator copy function faults – Yaskawa iQpump Drive User Manual User Manual

Page 148

Advertising
background image

6.6 Digital Operator COPY Function Faults

148

YASKAWA TM.iQp.01 iQpump Drive User Manual

6.6

Digital Operator COPY Function Faults

These faults can occur occurred during the operator COPY function. Fault content is displayed on the operator. An error during the

COPY function does not activate the fault contact output or alarm output.

Table 6.6 Digital Operator COPY Function Faults

Function

Digital Operator Display

Probable Causes

Corrective Action

READ

Function

PRE

READ IMPOSSIBLE

o3-01 was set to 1 to write a parameter when the
digital operator was write-protected (o3-02 = 0).

Set o3-02 to 1 to enable writing parameters with
the digital operator.

IFE

READ DATA ERROR

The read data length does not agree.

The write data is incorrect.

• Repeat the Read.
• Check the digital operator cable.
• Replace digital operator.

RDE

DATA ERROR

An attempted write of a parameter to EEPROM on

the digital operator failed.

• A low Inverter voltage has been detected.
• Repeat the read.
• Replace digital operator.

COPY

Function

CPE

ID UNMATCHED

The iQpump product code or software number is
different.

Use COPY function for the same product code and
software number.

VAE

INV. KVA UNMATCH

The capacity of the iQpump being copied and the

capacity in the digital operator are different.

Use COPY function for the same iQpump drive

capacity.

CRE

CONTROL UNMATCHED

The control method of the iQpump being copied and
the control method in the digital operator are

different.

Use the COPY function for the same control
method.

CYE

COPY ERROR

The parameter written to the iQpump was compared
with the parameter in the digital operator and they

were different.

COPY retest.

CSE

SUM CHECK ERROR

The checksum in the iQpump parameter area was
compared with the checksum in the digital operator

parameter area and they were different.

Retry the copy.

Verify

Function

VYE

VERIFY ERROR

The set value of the digital operator and the iQpump
do not match.

Retry Verify function.
After COPY is retested, Verify is retested.

Advertising