C.1 Standard iQpump Drive Specifications

YASKAWA

TM.iQp.01 iQpump Drive User Manual

205

◆ 480 VAC

Table C.2 480 VAC iQpump Drive Specifications

Table C.2 480 VAC iQpump Drive Specifications (Continued)

Model Number CIMR-P7U‰-107

40P4

40P7

41P5

42P2

43P7

45P5

47P5

49P0

4011

4015

4018

O

u

tput

Ratin

g

s

Rated output capacity (kVA)

1.4

1.6

2.8

4.0

5.8

9.5

13.0

16.0

21.0

26.0

30.0

Motor HP (460V)

0.5/0.75

1

1.5/2

3

5

7.5

10

15

20

25

30

Rated output current (A)

1.8

2.1

3.7

5.3

7.6

12.5

17.0

21.0

27.0

34.0

40.0

Max. output voltage (V)

3-phase; 380, 400, 415, 440, 460, or 480 VAC (Proportional to input voltage.)

Max. output frequency (Hz)

120 Hz

Pow

e

r Supp

ly

Char

acte

ri

s

ti

cs

Rated voltage (V)
Rated frequency (Hz)

3-phase, 380, 400, 415, 440, 460 or 480 VAC, 50/60 Hz

Rated input current (A)

2.2

2.5

4.4

6.4

9.0

15

20

26

33

40

48

Allowable voltage fluctuation

+ 10%, - 15%

Allowable frequency fluctuation

±5%

Control

Char

act

er

ist

ics

Measures for
power supply
harmonics

DC Reactor

Optional

12-pulse
Rectification

Not possible

Model Number CIMR-P7U‰-107

4024

4030

4037

4045

4055

4075

4090

4110

4160

4185

4220

4300

O

u

tput

Ra

ti

ng

s

Rated output capacity (kVA)

40.0

51.0

59.0

73.0

95.0

120.0

140.0

180.0

230.0

315.0

390.0

510.0

Motor HP (460V)

40

50

60

75

100

125

150

200

250

300/350

400/450

500+

Rated output current (A)

52.0

67.2

77.0

96.0

125.0

156.0

180.0

240.0

304.0

414.0

515.0

675.0

Max. output voltage (V)

3-phase, 380, 400, 415, 440, 460 or 480 VAC (Proportional to input voltage)

Max. output frequency (Hz)

120 Hz

Pow

er

Suppl

y

C

h

ar

a

ct

e

ri

st

ic

s

Max. voltage (V)
Rated frequency (Hz)

3-phase, 380, 400, 415, 440, 460, or 480 VAC, 50/60 Hz

Rated input current (A)

57

74

85

106

134

172

198

264

334

456

567

743

Allowable voltage fluctuation

+ 10%, - 15%

Allowable frequency fluctuation

±5%

Control

Char

act

eri

s

ti

cs

Measures for power
supply harmonics

DC Reactor

Built-in

12-Pulse
Rectification

Possible

Note:

The maximum applicable motor output is given for a standard 4-pole motor. When selecting the actual motor and Drive, be sure that the Drive's rated output current is
applicable for the motor's rated current.
A 3-wire phase-shifting transformer is required on the power supply for 12-pulse rectification.