Table 4 Fault History List

Parameter No.

Modbus

Address

Fault History

U3-01

0090H

Most Recent Fault
Last Fault

U3-02

0091H

2nd Most Recent Fault
Fault Message 2

U3-03

0092H

3rd Most Recent Fault
Fault Message 3

U3-04

0093H

4th Most Recent Fault
Fault Message 4

U3-05

0094H

Cumulative Operation Time at Most Recent Fault
Elapsed Time 1

U3-06

0095H

Cumulative Operation Time at 2nd Most Recent Fault
Elapsed Time 2

U3-07

009BH

Cumulative Operation Time at 3rd Most Recent Fault
Elapsed Time 3

U3-08

0097H

Cumulative Operation Time at 4th Most Recent Fault
Elapsed Time 4

U3-09

0804H

5th Most Recent Fault
Fault Message 5

U3-10

0805H

6th Most Recent Fault
Fault Message 6

U3-11

0806H

7th Most Recent Fault
Fault Message 7

U3-12

0807H

8th Most Recent Fault
Fault Message 8

U3-13

0808H

9th Most Recent Fault
Fault Message 9

U3-14

0809H

10th Most Recent Fault
Fault Message 10

U3-15

080EH

Cumulative Operation Time at 5th Most Recent Fault
Elapsed Time 5

U3-16

080FH

Cumulative Operation Time at 6th Most Recent Fault
Elapsed Time 6

U3-17

0810H

Cumulative Operation Time at 7th Most Recent Fault
Elapsed Time 7

U3-18

0811H

Cumulative Operation Time at 8th Most Recent Fault
Elapsed Time 8

U3-19

0812H

Cumulative Operation Time at 9th Most Recent Fault
Elapsed Time 9

U3-20

0813H

Cumulative Operation Time at 10th Most Recent Fault
Elapsed Time 10

Note:

Faults such as CPF00, CPF01, CPF02, CPF03, UV1, and UV02 are not stored in fault history.