history Configure history

buckets Requested buckets of intervals. Default is 50 buckets

interval Interval to sample data for each bucket. Default is 1800 seconds

Default:

N/A

Usage Guide:

To configure RMON History Configuration for specific interface

Example:

To configure RMON History Configuration as below table for GigabitEthernet X/X

Switch# configure terminal

Switch (config)# interface GigabitEthernet X/X

Switch (config-if) # rmon collection history 1 buckets 5 interval 3

4.2.56.105 rmon collection stats

Command:

rmon collection stats <1-65535>

rmon Configure Remote Monitoring on an interface

collection Configure Remote Monitoring Collection on an interface

stats Configure statistics

Default:

0

Usage Guide:

To configure RMON Statistics Configuration for specific interface

Example:

To configure RMON Statistics Configuration (2) as below table for GigabitEthernet X/X