43 erps <1-64> mep – PLANET MGSW-28240F User Manual

Page 73

Advertising
background image

Command Guide of MGSW-28240F

<1-64> ERPS group number

interconnect Major ring is interconnected

Default:

0

Usage Guide:

To create a profile and configure the Major ERPS interface port 0, port 1.

Example:

To create a profile 1 and configure the Major ERPS interface port 0(GigabitEthernet 1/1), port 1(GigabitEthernet 1/2)

without interconnected mode

Switch# configure terminal

Switch (config)# erps 1 major port0 interface GigabitEthernet 1/1 port1 interface

GigabitEthernet 1/2

4.2.43 erps <1-64> mep

Command:

erps <1-64> mep port0 sf <p0_sf: 1-100> aps <p0_aps: 1-100> port1 sf <p1_sf: 1-100>

aps <p1_aps: 1-100>

<1-64> ERPS group number

<p0_sf: 1-100> Index of Port 0 SignalFail MEP

<p0_aps: 1-100> Index of Port 0 APS MEP

<p1_sf: 1-100> Index of Port 1 SignalFail MEP

<p1_aps: 1-100> Index of Port 1 APS MEP

Default:

0

Usage Guide:

To configure ERPS Instance Data for specific ERPS profile.

Example:

To configure ERPS Instance Data(Port0: SF MEP = 2, APS MEP = 1. Port1: SF MEP = 4, APS MEP = 3) for specific

ERPS profile(1).

Switch# configure terminal

Switch (config)# erps 1 mep port0 sf 2 aps 1 port1 sf 4 aps 3

-73-

Advertising