116 mep <instance> cc – PLANET MGSW-28240F User Manual

Page 231

Advertising
background image

Command Guide of MGSW-28240F

To configure APS of MEP 1 as below table

Switch# configure terminal

Switch (config)# mep 1 aps 7 laps

4.2.116 mep <Instance> cc

Command:

mep <Instance> cc <Prio : 0-7> fr100s | fr10s | fr1m | fr1s | fr300s | fr6h | fr6m

mep Maintenance Entity Point

<Instance> The MEP instance number.

cc Continuity Check

<Prio : 0-7> Priority in case of tagged OAM. In the EVC domain this is the COS-ID.

fr100s Frame rate is 100 f/s.

fr10s Frame rate is 10 f/s.

fr1m Frame rate is 1 f/min.

fr1s Frame rate is 1 f/s.

fr300s Frame rate is 300 f/s.

fr6h Frame rate is 6 f/hour.

fr6m Frame rate is 6 f/min.

Default:

Usage Guide:

To configure CC of MEP

Example:

To configure CC of MEP 1 as below table

Switch# configure terminal

Switch (config)# mep 1 cc 2 fr10s

-231-