Command Guide of MGSW-28240F

mep <Instance> lck fr1m | fr1s

mep Maintenance Entity Point

<Instance> The MEP instance number.

lck Locked Signal

fr1m Frame rate is 1 f/min.

fr1s Frame rate is 1 f/s.

Default:

1 frame/sec

Usage Guide:

To configure Locked Frame Rate of MEP.

Example:

To configure Locked Frame Rate (1 frame/sec) of MEP 2.

Switch# configure terminal

Switch (config)# mep 2 lck

Switch (config)# mep 2 lck fr1s

4.2.127 mep <Instance> level

Command:

mep <Instance> level <Level : 0-7>

mep Maintenance Entity Point

<Instance> The MEP instance number.

level The MEG level of the MEP

<Level : 0-7> The MEG level value

Default:

0

Usage Guide:

To configure MEG level of MEP.

Example:

To configure MEG level (2) of MEP 2.