Command Guide of MGSW-28240F
mep <Instance> lck fr1m | fr1s
mep Maintenance Entity Point
<Instance> The MEP instance number.
lck Locked Signal
fr1m Frame rate is 1 f/min.
fr1s Frame rate is 1 f/s.
Default:
1 frame/sec
Usage Guide:
To configure Locked Frame Rate of MEP.
Example:
To configure Locked Frame Rate (1 frame/sec) of MEP 2.
Switch# configure terminal
Switch (config)# mep 2 lck
Switch (config)# mep 2 lck fr1s
4.2.127 mep <Instance> level
Command:
mep <Instance> level <Level : 0-7>
mep Maintenance Entity Point
<Instance> The MEP instance number.
level The MEG level of the MEP
<Level : 0-7> The MEG level value
Default:
0
Usage Guide:
To configure MEG level of MEP.
Example:
To configure MEG level (2) of MEP 2.