Efficient Networks Siemens Sinamics S120 User Manual

Page 265

Advertising
background image

Function modules

7.9 Basic positioner

Drive Functions
Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

265

When "flying referencing" during incremental positioning (relative) you can select whether

the offset value is to be taken into account for the travel path or not (p2603).
The "flying referencing" is activated by a 0/1 edge at binector input p2595 (start referencing).

The signal in binector input p2595 (start homing) must be set during the entire referencing

process otherwise the process is aborted.
Status bit r2684.1 (passive/flying referencing active) is linked with binector input p2509

(activate measurement probe evaluation). It activates measurement probe evaluation.

Binector inputs p2510 (measurement probe selection) and p2511 (measurement probe edge

evaluation) can be used to set which measurement probe (1 or 2) and which measurement

edge (0/1 or 1/0) is to be used.
The measurement probe pulse is used to supply connector input p2660 (home measurement

value) with the measurement via parameter r2523. The validity of the measurement is

reported to binector input p2661 (measurement valid feedback) via r2526.2.

Note
The following must always apply to the "Flying referencing mode" windows:
p2602 (outer window) > p2601 (inner window).
See function diagram 3614 for more information on the "Flying referencing mode" function.


The following then happens:
● If the drive has not yet been homed, status bit r2684.11 (reference point set) is set to "1".
● If the drive has already been homed, status bit r2684.11 (reference point set) is not reset

when starting flying referencing.

● If the drive has already been homed and the position difference is less than the inner

window (p2601), the old actual position value is retained.

● If the drive has already been homed and the position difference is more than the outer

window (p2602), warning A07489 (reference point offset outside window 2) is output and

the status bit r2684.3 (pressure mark outside window 2) set. No offset to the actual

position value is undertaken.

● If the drive has already been referenced and the absolute value of the position difference

is greater than the inner window (p2601) and less the outer window (p2602), then the

position actual value is corrected.

Note
Flying referencing is not an active operating mode. It is superimposed by an active operating

mode.
In contrast to searches for reference, flying referencing can be carried out superimposed by

the machine process.
As standard, for flying referencing, measuring probe evaluation is used; when enabled, the

measuring probe is selected (p2510) and the edge evaluation (p2511) (in the factory setting,

measuring probe 1 is always the measuring probe, flank evaluation in the factory setting is

always the 0/1 edge).