Communication PROFIBUS DP/PROFINET IO
10.1 Communications according to PROFIdrive
Drive Functions
368
Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4
Bit
Meaning
Comments
BICO
1
Power-on disable
A restart is only possible by means of OFF1 and
then ON.
6
Power-on disable
0
No power-up inhibit
Power-up is possible.
BO: r0899.6
1
Alarm present
The drive is operational again. No
acknowledgement necessary.
The active alarms are stored in the alarm buffer.
7
Alarm present
0
No alarm present
No active alarm in the alarm buffer.
BO: r2139.7
1
Setpoint-actual value monitoring within tolerance
band
Actual value within a tolerance bandwidth;
The tolerance bandwidth can be parameterized.
8
Following error within the tolerance
range
0
Setpoint/actual value monitoring not within
tolerance band
BO: r2684.8
1
Control required
The PLC is requested to assume control. Condition
for applications with isochronous mode: drive
synchronized with PLC system.
9
Control requested
0
Local operation
Control only possible on device
BO: r0899.9
1
Target position reached
10 Target position reached
0
Target position not reached
BO: r2684.10
1
Reference point set
11 Reference point set
0
Reference point not set
BO: r2684.11
0/1
Acknowledgement, traversing block
12 Acknowledgement, traversing
block activated
0
No effect
BO: r2684.12
1
Drive at standstill
13 Drive at standstill
0
Drive not at standstill
BO: r2199.0
14 Reserved
–
–
–
15 Reserved
–
–
–
STW2 (status word 2)
See function diagram [2454]
Table 10-13 Description of STW2 (status word 2)
Bit
Meaning
Comments
BICO
0
DDS eff., bit 0
–
BO: r0051.0
1
DDS eff., bit 1
–
BO: r0051.1
2
DDS eff., bit 2
–
BO: r0051.2
3
DDS eff., bit 3
–
Drive data set effective (5-bit counter)
BO: r0051.3