Basic information about the drive system

12.7 Examples of replacing components

Drive Functions
Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

501

Action

Reaction

Comments

Set p9905 to "1"

Alarm disappears

The serial number is copied

to the target topology

The serial number is stored in

the RAM of the Control Unit and

has to be copied to the non-

volatile memory with p0971 or

p0977.

The component has been successfully replaced

Example: Replacing a Motor Module/Power Module with a different power rating

Precondition:

The replaced power unit has a different power rating
Vector: Power rating of the Motor Module/Power Module not greater than 4 * motor current

Table 12-13 Example: Replacing a power unit with a different power rating

Action

Reaction

Comments

Switch off the power supply

Replace the defective

component and connect the

new one

Switch on the power supply





Alarm A01420

Drive Object CU:
– p0009 = 1
– p9906 = 2
– p0009 = 0
– p0977 = 1


Device configuration

Component comparison

Completing the configuration

Data Backup

For p9906=2: Caution
Topology monitoring for all

(!) components heavily

reduced so that DRIVE-CLiQ

lines may be hidden by

mistake.

Drive Object component:
– p0201 = r0200
– p0010 = 0
– p0971 = 1


Use the code number

Completing commissioning

Data Backup

The new order number is

stored in the RAM of the

Control Unit and has to be

copied to the non-volatile

memory with p0971 or

p0977.

The component has been successfully replaced