Basic information about the drive system

12.4 BICO technology: interconnecting signals

Drive Functions

482

Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

%2%LQHFWRURXWSXW

6LJQDOVRXUFH

%,%LQHFWRULQSXW

6LJQDOVLQN

2))

2))

2))

'ULYH

'ULYH

2))

2))

2))

U

',

;

9

S&



S&



S&



S&



Figure 12-8 Connection of OFF3 to several drives (example)

12.4.6

BICO technology

BICO interconnections to other drives

The following parameters are available for BICO interconnections to other drives:
● r9490 Number of BICO interconnections to other drives
● r9491[0...15] BI/CI of BICO interconnections to other drives
● r9492[0...15] BO/CO of BICO interconnections to other drives
● p9493[0...15] Reset BICO interconnections to other drives

Copying drives

When a drive is copied, the interconnection is copied with it.

Binector-connector converters and connector-binector converters

Binector-connector converter

● Several digital signals are converted to a 32-bit integer double word or to a 16-bit integer

word.

● p2080[0...15] BI: PROFIdrive PZD send bit-serial

Connector-binector converter

● A 32-bit integer double word or a 16-bit integer word is converted to individual digital

signals.

● p2099[0...1] CI: PROFIdrive PZD selection receive bit-serial